Fluke 1630-2FC Earth Ground Clamp Meter in BD

৳ 299,000.00৳ 310,000.00 (-4%)

In stock

Features

  • AC leakage current measurement – identify ac leakage currents without disconnecting the earth ground stake from the grounding system – ideal for system troubleshooting
  • Rugged – heavy-duty clamp jaw stays in alignment and in calibration even in every day, on the job industrial environments
  • Logging measurements – the earth ground clamp saves time by automatically recording data at pre-set intervals and saves up to 32,760 measurements in memory at the set logging interval
  • Alarm threshold – user-defined high/low alarm limits, for rapid measurement evaluation
  • Band-pass filter – selectable band-pass filter function removes unwanted noise from the ac leakage current measurement
  • Fluke Connect compatible

Fluke 1630-2 FC:

Stake less earth ground loop and AC leakage current clamp for fast, safe indoor/outdoor earth ground resistance and AC leakage current tests.

For use to test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not allow driving auxiliary test stakes. Remain on line – this earth ground clam meter identifies ground loop resistance without having to disconnect then reconnect the earth electrode from the system.

Additionally, this clamp meter is a rugged tool that comes equipped with a heavy-duty clamp jaw which stays in alignment and calibration even in every day, on-the-job industrial environments.

Fluke 1630-2 FC Specifications

Electrical Specifications
Maximum Voltage to Earth Ground 1000 V
Frequency Range 40 Hz to 1 kHz
Overload Indication OL
Data Logging Capacity Minimum of 32,760 measurements
Data Logging Interval 1 second to 59 minutes and 59 seconds
Display Reading Specification with Standard Loop Resistance
Input (Ω) 0.474
0.5
10
100
Minimum 0.417
0.443
9.55
96
Maximum 0.531
0.558
10.45
104
Safety
General IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1
Measurement IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V
Current Clamp for Leakage Current Measurements IEC/EN 61557-13: Class 2, ≤30 A/m
Resistance to Earth IEC/EN 61557-5
Effectiveness of the Protective Measures IEC/EN 61557-16
Electromagnetic Compatibility (EMC) International: IEC/EN 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class B, IEC/EN 61326-2-2
Korea (KCC): Class A equipment (Industrial broadcast and communications equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Wireless Radio
Frequency Range 2412 to 2462 MHz
Output Power <10 mW
Radio Frequency Certification FCC ID:T68-FBLE IC:6627A-FBLE
General Specifications
Battery Type: 4 x AA Alkaline batteries (IEC/EN LR6)
Life: More than 15 hours
Ingress Protection IEC/EN 60529: IP30 with jaw closed
LCD Digital reading: 9999 counts
Refresh rate: 4 per second
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature 4 to 140°F (-20 to 60°C)
Operating Humidity Non condensing (<50°F) (<10 °C)
≤90% RH (at 50 to 86°F [10 to 30°C])
≤75% RH (at 86 to 104°F [30 to 40°C])
≤45% RH (at 104 to 122°F [40 to 50°C])
Reference Temperature 73 ±9°F (23 ±5°C)
Temperature Coefficient 0.15% x (specified accuracy)/°C (<64.4 or >82.4°F [<18 or >28°C])
Operating Altitude 6561′ (2000 m)
Storage Altitude 39,370′ (12,000 m)
Dimensions 11.1 x 4.1 x 1.9″ (283 x 105 x 48 mm)
Weight 1.94 lbs (880 g)
Be the first to review “Fluke 1630-2FC Earth Ground Clamp Meter in BD”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

See It Styled On Instagram

    No access token

Main Menu