The rugged testo 350 exhaust gas analyzer is ideal for a wide range of professional industrial emission measurements and analysis applications, and is excellently suited for complex data compilation.
The testo 350 exhaust gas analyzer is made up of two separate units
The testo 350 Control Unit is used to control emission measurements. It has a clearly structured graphic display, and four different menu applications to choose from, including burner / gas turbine / motors / user-defined applications. The instructions on the display guide you through the measurement and make the steps leading up to it easier. This saves both time and hassle. The Control Unit can also be used to control the Analysis Box when it is not at the exhaust gas pipe or measurement site. This is advisable when working on larger systems.
The testo 350 Analysis Box contains the sensor system and electronics. It comes standard equipped with an O2 gas sensor. At least one more sensor (maximum of six) is needed to operate the Box. Optional sensors include sensors for CO, CO2, NO, NO2, SO2, H2S and CxHy.The increased measuring range (thinning) allows you to carry out unlimited measurements with higher gas concentrations. It is automatically activated when gas concentrations are unexpectedly high. The measuring range of a selected sensor can be increased by a certain factor. An opening on the underside gives you access to the relevant service and wearing parts, such as pumps and filters. The testo 350 also has numerous diagnosis functions with easy to understand readings and information. The analyzer constantly displays the current reading.
The Analysis Box can be controlled by the Control Unit or operated via USB, Bluetooth® 2.0, or CANCase from a PC or notebook. After the Analysis Box has been programmed, it can carry out measurements independently, save the results, and transfer the data to the Control Unit.
Conducting industrial emission measurements with the testo 350
The testo 350 exhaust gas analyzer has been specially designed for carrying out industrial emission measurements in the field. In the tab “Applications” you can find out more about:
►Emission measurements on industrial motors
►Emission measurements on burners
►Emission measurements on gas turbines
►Emission measurements on thermo processes
Delivery Scope
testo 350, O2 sensor, differential pressure sensor, type K NiCr-Ni and type S temperature sensor port, Pt10Rh-Pt, testo data bus port, rechargeable battery, built in combustion air sensor (NTC), trigger port, data memory, carrying strap set for the Control Unit and Analysis Box, USB interface and calibration certificate.
Technical Data
Temperature – NTC
Measuring range
-4° to 122 °F / -20 to +50 °C
Accuracy
±0.4 °F (14° to 122 °F) / ±0.2 °C (-10 to +50 °C)
Resolution
0.1 °F (-4° to 122 °F) / 0.1 °C (-20 to +50 °C)
Ambient temperature probe
Temperature – Type K TC
Measuring range
-328.0° to 2498.0 °F / -200 to +1370 °C
Accuracy
±0.7 °F (-148.0° to 392.0 °F) / ±0.4 °C (-100 to +200 °C)
±1.8 °F (-328.0° to -148.2 °F) / ±1 °C (-200 to -100.1 °C)
±1.8 °F (392.2° to 2498.0 °F) / ±1 °C (200.1 to +1370 °C)
Resolution
±0.1 °F (-328.0° to 2498.0 °F) / 0.1 °C (-200 to +1370 °C)
Temperature – TC Type S (Pt10Rh-Pt)
Measuring range
32.0° to 3200.0 °F / 0 to +1760 °C
Accuracy
±1.8 °F (32.0° to 3200.0 °F) / ±1 °C (0 to +1760 °C)
Resolution
±0.1 °F (32.0° to 3200.0 °F) / 0.1 °C (0 to +1760 °C)
Differential Pressure
Measuring range
-16 to +16 InH₂O / -40 to +40 hPa
-80 to +80 InH₂O / -200 to +200 hPa
Accuracy
±1.5 % of mv (-16 to -1 InH₂O) / ±1.5 % of mv (-40 to -3 hPa)
±1.5 % of mv (+1 to +16 InH₂O) / ±1.5 % of mv (+3 to +40 hPa)
±0.01 InH₂O (-1.20 to +1.20 InH₂O) / ±0.03 hPa (-2.99 to +2.99 hPa)
±1.5 % of mv (-80 to -20 InH₂O) / ±1.5 % of mv (-200 to -50 hPa)
±1.5 % of mv (+20 to +80 InH₂O) / ±1.5 % of mv (+50 to +200 hPa)
±0.2 InH₂O (-20.0 to +20.0 InH₂O) / ±0.5 hPa (-49.9 to +49.9 hPa)
Resolution
0.01 InH₂O (-16 to +16 InH₂O) / 0.01 hPa (-40 to +40 hPa)
0.1 InH₂O (-80 to +80 InH₂O) / 0.1 hPa (-200 to +200 hPa)
Absolute Pressure
Measuring range
240 to +460 InH₂O / 600 to +1150 hPa
Accuracy
±4 InH₂O / ±10 hPa
Resolution
1 InH₂O / 1 hPa
Flue gas O₂
Measuring range
0 to +25 Vol.%
Accuracy
±0.8% of fsv (0 to +25 Vol.%)
Resolution
0.01 Vol.% (0 to +25 Vol.%)
Reaction time t₉₀
20 sec (t95)
Flue gas CO
Measuring range
0 to +10000 ppm
Accuracy
±5 % of mv (+200 to +2000 ppm)
±10 % of mv (+2001 to +10000 ppm)
±10 ppm (0 to +199 ppm)
Resolution
1 ppm (0 to +10000 ppm)
Reaction time t₉₀
40 sec
H₂ only as an indicator
Flue gas COlow
Measuring range
0 to 500 ppm
Accuracy
±5 % of mv (+40 to +500 ppm)
±2 ppm (0 to +39.9 ppm)
Resolution
0.1 ppm (0 to +500 ppm)
Reaction time t₉₀
40 sec
H₂ only as an indicator
Flue Gas NO
Measuring range
0 to +4000 ppm
Accuracy
±5 % of mv (+100 to +1999 ppm)
±10 % of mv (+2000 to +4000 ppm)
±5 ppm (0 to +99 ppm)
Resolution
1 ppm (0 to +4000 ppm)
Reaction time t₉₀
30 sec
Flue gas NOlow
Measuring range
0 to +300 ppm
Accuracy
±5 % of mv (+40 to +300 ppm)
±2 ppm (0 to +39.9 ppm)
Resolution
±0.1 ppm (0 to +300 ppm)
Reaction time t₉₀
30 sec
Flue Gas NO₂
Measuring range
0 to +500 ppm
Accuracy
±5 % of mv (+100 to +500 ppm)
±5 ppm (0 to +99.9 ppm)
Resolution
0.1 ppm (0 to +500 ppm)
Reaction time t₉₀
40 sec
Flue Gas SO₂
Measuring range
0 to +5000 ppm
Accuracy
±5 % of mv (+100 to +2000 ppm)
±10 % of mv (+2001 to +5000 ppm)
±5 ppm (0 to +99 ppm)
Resolution
1 ppm (0 to +5000 ppm)
Reaction time t₉₀
30 sec
Efficiency (calculated)
Measuring range
0 to +120 %
Resolution
0.1 % (0 to +120 %)
Flue Gas loss (calculated)
Measuring range
0 to +99.9 %
Resolution
0.1 % (0 to +99.9 %)
Flue Gas dewpoint (calculated)
Measuring range
0 to +99.9 °Ctd
Resolution
0.1 °Ctd (0 to +99.9 °Ctd)
Flue Gas CO₂ calculation (calculated from O₂)
Measuring range
0 to CO₂ max
Accuracy
calculated from O₂ ±0.2 Vol.%
Resolution
0.01 Vol.%
Flue gas H₂S
Measuring range
0 to +300 ppm
Accuracy
±5 % of mv (+40 to +300 ppm)
±2 ppm (0 to +39.9 ppm)
Resolution
0.1 ppm (0 to +300 ppm)
Reaction time t₉₀
35 sec
Flue Gas CO₂ – NDIR
Measuring range
0 to +50 Vol.%
Accuracy
±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%)
±0.5 Vol.% + 1.5 % of mv (>25 to 50 Vol.%)
Resolution
0.01 Vol.% (0 to 25 Vol.%)
0.1 Vol.% (> 25 Vol.%)
Reaction time t₉₀
10 sec
Velocity / Volume flow
Measuring range
0 to +7874 fpm / 0 to +40 m/s
Resolution
19.7 fpm (0 to +7874 fpm) / 0.1 m/s (0 to +40 m/s)
Methane (CH₄)
Measuring range
100 to 40000 ppm
Accuracy
< 400 ppm (100 to 4000 ppm)
< 10 % of mv (> 4000 ppm)
Resolution
10 ppm
Min. O₂ requirement in flue gas
2 % + (2 x mv methane)
Reaction time t₉₀
< 40 sec
Response factor
1
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Propane (C₃H₈)
Measuring range
100 to 21000 ppm
Accuracy
< 400 ppm (100 to 4000 ppm)
< 10 % of mv (> 4000 ppm)
Resolution
10 ppm
Min. O₂ requirement in flue gas
2 % + (5 x mv propane)
Reaction time t₉₀
< 40 sec
Response factor
1.5
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Butane (C₄H₁₀)
Measuring range
100 to 18000 ppm
Accuracy
< 400 ppm (100 to 4000 ppm)
< 10 % of mv (> 4000 ppm)
Resolution
10 ppm
Min. O₂ requirement in flue gas
2 % + (6.5 x mv butane)
Reaction time t₉₀
< 40 sec
Response factor
2
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
General technical data
Weight
169 oz. / 4800 g
Dimensions
13 x 5 x 17 in. / 330 x 128 x 438 mm
Operating temperature
23.0° to 113.0 °F / -5 to +45 °C
Housing
ABS
Protection class
IP40
Connectable probes
1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure
Product colour
Black
Battery type
lithium batteries
Battery life
5 h
Power supply
AC mains unit 100V to 240V (50 to 60 Hz)
DC electric tension input
11V to 40V
Pump flow
1 l/min. with through-flow monitoring
Hose length
16.2 m (corresponds to 5 probe hose extensions)
Max. pos. press./flue gas
0.725 psi / 50 mbar
Max. neg. press./flue gas
-4.351 psi / -300 mbar
Max. dust load
20 g/m³ dust in flue gas
Dewpoint calculation
0 °Ctd; 99 °Ctd
Max. humidity load
70 °C dewpoint temperature
Trigger input
Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA
Maximum
250,000 readings
Interface
data bus; Bluetooth®; USB; IR/IRDA interface; Mains connection; trigger input; Differential Pressure; probe input/ probe inputs; DC-voltage input; dilution gas inlet for measurement range extension
Storage temperature
-4.0° to 122.0 °F / -20 to +50 °C
Be the first to review “Testo 350 Portable Emissions Analyzer Price in BD”
Reviews
There are no reviews yet.