Fluke 1630-2FC Earth Ground Clamp Meter in BD
৳ 299,000.00৳ 310,000.00 (-4%)
Features
- AC leakage current measurement – identify ac leakage currents without disconnecting the earth ground stake from the grounding system – ideal for system troubleshooting
- Rugged – heavy-duty clamp jaw stays in alignment and in calibration even in every day, on the job industrial environments
- Logging measurements – the earth ground clamp saves time by automatically recording data at pre-set intervals and saves up to 32,760 measurements in memory at the set logging interval
- Alarm threshold – user-defined high/low alarm limits, for rapid measurement evaluation
- Band-pass filter – selectable band-pass filter function removes unwanted noise from the ac leakage current measurement
- Fluke Connect compatible
Fluke 1630-2 FC:
Stake less earth ground loop and AC leakage current clamp for fast, safe indoor/outdoor earth ground resistance and AC leakage current tests.
For use to test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not allow driving auxiliary test stakes. Remain on line – this earth ground clam meter identifies ground loop resistance without having to disconnect then reconnect the earth electrode from the system.
Additionally, this clamp meter is a rugged tool that comes equipped with a heavy-duty clamp jaw which stays in alignment and calibration even in every day, on-the-job industrial environments.
Fluke 1630-2 FC Specifications
| Electrical Specifications | |
| Maximum Voltage to Earth Ground | 1000 V |
| Frequency Range | 40 Hz to 1 kHz |
| Overload Indication | OL |
| Data Logging Capacity | Minimum of 32,760 measurements |
| Data Logging Interval | 1 second to 59 minutes and 59 seconds |
| Display Reading Specification with Standard Loop Resistance | |
| Input (Ω) | 0.474 0.5 10 100 |
| Minimum | 0.417 0.443 9.55 96 |
| Maximum | 0.531 0.558 10.45 104 |
| Safety | |
| General | IEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1 |
| Measurement | IEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V |
| Current Clamp for Leakage Current Measurements | IEC/EN 61557-13: Class 2, ≤30 A/m |
| Resistance to Earth | IEC/EN 61557-5 |
| Effectiveness of the Protective Measures | IEC/EN 61557-16 |
| Electromagnetic Compatibility (EMC) | International: IEC/EN 61326-1: Portable Electromagnetic Environment CISPR 11: Group 1, Class B, IEC/EN 61326-2-2 Korea (KCC): Class A equipment (Industrial broadcast and communications equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
| Wireless Radio | |
| Frequency Range | 2412 to 2462 MHz |
| Output Power | <10 mW |
| Radio Frequency Certification | FCC ID:T68-FBLE IC:6627A-FBLE |
| General Specifications | |
| Battery | Type: 4 x AA Alkaline batteries (IEC/EN LR6) Life: More than 15 hours |
| Ingress Protection | IEC/EN 60529: IP30 with jaw closed |
| LCD | Digital reading: 9999 counts Refresh rate: 4 per second |
| Operating Temperature | 14 to 122°F (-10 to 50°C) |
| Storage Temperature | 4 to 140°F (-20 to 60°C) |
| Operating Humidity | Non condensing (<50°F) (<10 °C) ≤90% RH (at 50 to 86°F [10 to 30°C]) ≤75% RH (at 86 to 104°F [30 to 40°C]) ≤45% RH (at 104 to 122°F [40 to 50°C]) |
| Reference Temperature | 73 ±9°F (23 ±5°C) |
| Temperature Coefficient | 0.15% x (specified accuracy)/°C (<64.4 or >82.4°F [<18 or >28°C]) |
| Operating Altitude | 6561′ (2000 m) |
| Storage Altitude | 39,370′ (12,000 m) |
| Dimensions | 11.1 x 4.1 x 1.9″ (283 x 105 x 48 mm) |
| Weight | 1.94 lbs (880 g) |







Reviews