Fluke 754 Documenting Process Calibrator HART Price in BD

৳ 1,200,000.00৳ 1,250,000.00 (-4%)

In stock

The 753 and 754 Documenting Process Calibrators are battery-powered, hand-held instruments that measure and source electrical and physical parameters. In addition, the 754 supplies basic HART? communicator functions when used with HART-capable transmitters.
The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation. The 754 does the work of several tools – sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. Youメll fall in love with the new improved graphical screen, Li-on battery for longer life, USB port and new accessories to complete the package.

Features:

  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Holds up to a full week of downloaded procedures and calibration results.
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white dual display. Read both sourced and measured parameters simultaneously.
  • Multi lingual interface
  • Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge.
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
  • Delivered with DPC/Track Sample software.
  • Compatible with many Asset Management software packages.

Specifications:

Measurement Accuracy
Voltage DC      1 Year             2 Years
100.000 mV    0.02%+0.005 mV     0.03%+0.005 mV
3.00000 V     0.02%+0.00005 V     0.03%+0.00005 V
30.0000 V     0.02%+0.0005 V     0.03%+0.0005 V
300.00 V     0.05%+0.05 V     0.07%+0.05 V
Voltage AC  Range
40 to 500Hz  Resolution     1 Year             2 Years
3.000 V     0.001 V     0.5%+0.002 V     1.0%+0.004 V
30.00 V     0.01 V     0.5%+0.02 V     1.0%+0.04 V
300.0 V     0.1 V     0.5%+0.2 V     1.0%+0.2 V
Current DC                                 1 Year          2 Years
30.000 mA       0.01% + 5 uA      0.015%+7 uA
110.00 mA     0.01% + 20 uA     0.015%+30 uA
Resistance                            1 Year                 2 Years
10.000 O     0.05% + 50 mO     0.07%+70 mO
100.00 O     0.05% + 50 mO     0.07%+70 mO
1.0000 kO      0.05% + 500 mO     0.07%+0.5 O
10.000 kO     0.1% + 10 O     0.15%+15 O
Frequency      Resolution     Accuracy (2 Years)
1.00 to 110.00 Hz     0.01 Hz     0.05 Hz
110.1 to 1100.0 Hz     0.1 Hz     0.5 Hz
1.101 to 11.000 kHz      0.001 kHz     0.005 kHz
11.01 to 50.00 kHz     0.01 kHz     0.05 kHz
Source Accuracy
Voltage DC                                         1 Year     2 Years
100.000 mV   0.01%+0.005 mV     0.015%+0.005 mV
1.00000 V     0.01%+0.00005 V     0.015%+0.0005 V
15.0000 V     0.01%+0.0005 V     0.015%+0.0005 V
Current DC                                                       1 Year    2 Years
22.000 mA (Source)     0.01%+ 0.003 mA     0.02%+ 0.003 mA
Current Sink (Simulate) 0.02% + 0.007 mA     0.04% + 0.007 mA
Resistance                                       1 Year     2 Years
10.000 O       0.01% + 10 mO     0.015% + 15 mO
100.00 O       0.01% + 20 mO     0.015% + 30 mO
1.0000 kO     0.02% + 0.2 O     0.03% + 0.3 O
10.000 kO     0.02% + 3 O     0.03% + 5 O
Frequency      2 Years
0.1 to 10.99 Hz     0.01 Hz
0.01 to 10.99 Hz     0.01 Hz
11.00 to 109.99 Hz     0.1 Hz
110.0 to 1099.9 Hz     0.1 Hz
1.100 to 21.999 kHz     0.002 kHz
22.000 to 50.000 kHz     0.005 kHz
Technical Data
Data Log Functions Measure functions:     Voltage, current, resistance, frequency, temperature, pressure
Reading rate:     1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length:     8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions Source functions:     Voltage, current, resistance, frequency, temperature
Rate:     4 steps/second
Trip detect:     Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function Voltage:     Selectable, 26 V
Accuracy:     10%, 18 V minimum at 22 mA
Maximum current:     25 mA, short circuit protected
Maximum input voltage:     50 V DC
Step Functions Source Functions     Voltage, current, resistance, frequency, temperature
Manual Step     Selectable step, change with arrow buttons
Autostep     Fully programmable for function, start delay, stepvalue, time per step, repeat

 

Environmental Specifications
Operating Temperature  -10 °C to +50 °C
Storage Temperature -20 °C to +60 °C
Dust/water resistance Meets IP52, IEC 529
Operating Altitude 3000 m above mean sea level (9842 ft)

 

Mechanical & General Specifications
Size 136 x 245 x 63 mm (5.4モ x 9.6 x 2.5)
Weight 1.2 kg (2.7 lb)
Batteries Internal Battery Pack Li-ion:     7.2V, 4400mAh, 30 Wh
Battery Life  >8 hours typical
Battery Replacement Replace without opening calibrator; no tools required
Side port connections  Pressure module connector
USB Connector to interface to your PC
Digital instrument (HART) connector
Connection for optional battery charger/eliminator
Data storage capacity 1 week of calibration procedures results

 

Temperature, Resistance Temperature Detectors
Degrees or % of reading
Type (a) Range °C Measure °C1 Source current Source °C Allowable current
1 year 2 year 1 year 2 year
100 O Pt (385) -200 to 100
100 to 800
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04 % + 0.10 °C
1 mA 0.05 °C
0.0125 % + 0.04 °C
0.10 °C
0.025 % + 0.08 °C
0.1 mA to 10 mA
200 O Pt (385) -200 to 100
100 to 630
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04 % + 0.10 °C
500 µA 0.06 °C
0.017 % + 0.05 °C
0.12 °C
0.034 % + 0.10 °C
0.1 mA to 1 mA
500 O Pt (385) -200 to 100
100 to 630
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04 % + 0.10 °C
250 µA 0.06 °C
0.017% + 0.05 °C
0.12 °C
0.034 % + 0.10 °C
0.1 mA to 1 mA
1000 O Pt (385) -200 to 100
100 to 630
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04% + 0.10 °C
150 µA 0.06 C
0.017 % + 0.05 °C
0.12 C
0.034 % + 0.10 °C
0.1 mA to 1 mA
100 O Pt (3916) -200 to 100
100 to 630
0.07 °C
0.02 % +0.05 °C
0.14 °C
0.04 % +0.10 °C
1 mA 0.05 °C
0.0125 % + 0.04 °C
0.10 °C
0.025 % + 0.08 °C
0.1 mA to 10 mA
100 O Pt (3926) -200 to 100
100 to 630
0.08 °C
0.02 % +0.06 °C
0.16 °C
0.04 % +0.12 °C
1 mA 0.05 °C
0.0125 % + 0.04 °C
0.10 °C
0.025 % + 0.08 °C
0.1 mA to 10 mA
10 O Cu (427) -100 to 260 0.2 °C 0.4 °C 3 mA 0.2 °C 0.4 °C 0.1 mA to 10 mA
120 O Ni (672) -80 to 260 0.1 °C 0.2 °C 1 mA 0.04 °C 0.08 °C 0.1 mA to 10 mA