Novotest UD2301 Ultrasonic Flaw Detector Price in BD

৳ 175,000.00৳ 180,000.00 (-3%)

In stock

  • Price With Prove
  • Frequency range from 0 to 10 MHz, with smooth adjustment;

  • Display of a scale of scanning in microseconds and millimeters;

  • A-scan and B-scan;

  • DAC curve (by up to 16 points);

  • TVG mode (construction of 16 points);

  • DGS function, with automatic calculation of the equivalent reflector size;

  • Variable display orientation to work in any position of the device;

  • The device operates on standard AA batteries, as well as on conventional batteries, which makes them easy to replace;

  • Ergonomic shockproof case with protective rubber protectors;

  • Lightweight and compact size.

An ultrasonic flaw detector is designed to search for voids and inhomogeneities inside the materials under testing with ultrasound. It is the most common device in the world for non-destructive testing of metal (and other materials with low attenuation of ultrasonic waves) products in production, as well as objects in operation.

Ultrasonic Flaw Detector NOVOTEST UD2301 is a powerful, ergonomic, portable device that has all the functions of a general industrial ultrasonic flaw detectors and can be used in laboratories and workshops, and is perfect for field use.

The main advantages of the Ultrasonic Flaw Detector NOVOTEST UD2301 are below:

MULTIFUNCTIONAL

The device has wide functionality:

– presentation of the signal like A-scan and B-scan, which allows the operator to select the desired operating mode in accordance with the task;

– the device has two independent gates, with the ability to evaluate parameters in different areas on the scan, also using the automatic defect alarm function the limits can be configured individually for each gate.

– for better signal processing, the device has functions of freezing and envelope, which allows the user to more accurately evaluate the received data.

DAC AND TVG FUNCTIONS

The device implements the Distance Amplitude Correction (DAC) and Time Varied Gain (TVG) functions, with the setting up to 16 points, which allows the operator to evaluate the equivalent reflector size at various depths.

DGS FUNCTION

Also in the device there are Distance Gain Size (equivalent) diagrams that allow user to build an amplitude curve from one standard reflector, as well as calculate the equivalent reflector size of tested discontinuities.

ARCHIVE 

The device has an archive for storing measurements, settings for a specific object, settings of transducers to quickly switch settings when changing the testing object .

ANY DISPLAY ORIENTATION

A unique screen orientation function is implemented in the Ultrasonic Flaw Detector NOVOTEST UD2301, depending on the conditions under which the testing is performed, the screen orientation can be either vertical or horizontal. Also, the screen can be configured for both right-handed and left-handed people, i.e. the screen can be rotated 360°.

AUTONOMY

The device powered from three standard AA batteries, which makes the device completely independent of the stationary power source, the internal charger allows the battery to be charged from the standard USB 5V socket, with power bank the device can be used continuously for almost unlimited time.

DESIGN

The device has a transflective TFT display with a resolution of 480x320px, the enclosure is made in an ergonomic shape with a rubber bumper, which makes the device shockproof and resistant to falls. To connect the probes, standard connectors are used, which allows the operator to use any transducers without restrictions.

The device is supplied with PC software for uploading the measurement archive and processing the results.

Operating frequency range from 1 to 10,0 MHz
Range of measured time intervals (duration of scanning) from 6 to 1000 µs
Velocity range 1000 – 9999 m / s
Error of measurement of time intervals not exceed ± 0,025 µs
Maximum permissible error of measurement of the amplitudes of the signals at the receiver input in the range from 0 to 110 dB not exceed ± 0,5 dB
Testing gain range 125 dB
Averaging over the quantity of starts from 1 to 16
Range of variation of temporal sensitivity adjustment (TVG) 40 dB
Number of control points TVG 16
Duration of the excitation pulse to the load from 0,0 to 0,5 µs
Deviation of the amplitudes of input signals in the range from 10 to 100% of the screen height not more than 1 dB
Setting a delay in the prism of the probe from 0 to 15 µs
Detection of signals positive half-wave, radio mode
Standards
  • EN 12668
  • ASTM E1324
  • EN 55011
  • EN61000-6-2:2001
  • EN 61010-1:2014 (EN 61010-1:2010)
  • EN 60529:2014
  • EN ISO 16810:2016
  • SOU NNEC 027:2014
  • SOU NNEC 032:2014
  • SOU NNEC 038:2017
Dimensions (W*H*L) 80*162*38 mm
Weight, not more 250 g (without batteries)

Download Data Sheet

ULTRASONIC-FLAW-DETECTORS-NOVOTEST-UD2301

Al document collect from novotest website

Be the first to review “Novotest UD2301 Ultrasonic Flaw Detector Price in BD”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

See It Styled On Instagram

    No access token

Main Menu